For each skylight, confirm that the types, U-values, SHGCs, pitches, areas, shading, orientations and ceiling assignments which are entered into the software correspond with field-verified plans and/or field data collected by the Rater/RFI for the actual condition of the rated home.
SCORING: "Satisfactory" when correct or "Unsatisfactory" when incorrect. "N/A": No Skylights in the home.
GUIDANCE: *Window Area - QAD value within 5% of Rater/RFI value *SHGC / U-Value - Value in software corresponds with supporting docs or onsite verification *Roof Assignment / Orientation - Value in software corresponds with supporting docs or onsite verification *Pitch - Value in software matches roof pitch or within 1 (4/12 instead of 5/12)
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article