V8 Field QA Q16: Skylights

Modified on Tue, 5 May at 4:17 PM

On ridealong Field QA Reviews (remote or in-person), if applicable, does Rater/RFI verify and document the correct skylight combinations based on type, U-value, SHGC, pitch, orientation, overhang, shading and ceiling assignment? Does Rater/RFI take any measurements of the skylights to verify that plans and as-built skylights match, or take full skylights measurements if no plans? Does Rater/RFI verify skylight pitch while on-site?

SCORING: "Satisfactory": When no errors in verification "Unsatisfactory": When any errors in verification from list below "N/A": No Skylights present in the home

GUIDANCE: Skylights Verification Errors - The Rater/RFI can correctly identify or determine the following items: * As-Built Skylight Area matches Plans or other backup * Construction Type of Skylight (Frame Material & Glazing Type) * Orientation of each Skylight * As-Built Skylight Performance from NFRC labels (Solar heat gain coefficient (SHGC) & U-Value) * If NFRC labels not present, identify alternative methods to determine Skylight Performance using known window characteristics (NFRC Certified Products Directory, Table 4 in ASHRAE Handbook of Fundamentals, Chapter 5 or LBL RESFEN 6.0 User Manual, Table 5.5, or Efficient Window Collaborative window selection tool) * As-Built Pitch matches Plans or other backup

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article