For each duct system, Rater/RFI verifies and documents the correct area served, # of returns, associated heating/cooling equipment, locations, % areas of each location type, and R-values. Some duct locations are not visible at the time of field QA. Verify that percentages seem reasonable for conditions found. Photos of Duct R-Values and Location of Duct Work is recommended, but not required.
SCORING: "Satisfactory": No errors in verification "1": One Error (listed below) "2": Two Errors (listed below) "3": Three or More Errors or incorrectly identifying the number of duct systems (listed below) "N/A": No Duct Systems in the home
GUIDANCE: Duct Systems Verification Errors - The Rater/RFI can correctly identify or determine the following items per system: * Areas Served (i.e., per floor/room, etc. NOT specific square footage) * # of Returns * Associated Heating/Cooling Equipment Served by Duct System * Location of Duct Work (Attic (well vented), Attic (well vented, under insulation), Garage, etc.) * % Area of Each Location Type * Duct R-Values