V8 Field QA Q22: DuctSystems

Modified on Tue, 5 May at 4:17 PM

For each duct system, Rater/RFI verifies and documents the correct area served, # of returns, associated heating/cooling equipment, locations, % areas of each location type, and R-values. Some duct locations are not visible at the time of field QA. Verify that percentages seem reasonable for conditions found. Photos of Duct R-Values and Location of Duct Work is recommended, but not required.

SCORING: "Satisfactory": No errors in verification "1": One Error (listed below) "2": Two Errors (listed below) "3": Three or More Errors or incorrectly identifying the number of duct systems (listed below) "N/A": No Duct Systems in the home

GUIDANCE: Duct Systems Verification Errors - The Rater/RFI can correctly identify or determine the following items per system: * Areas Served (i.e., per floor/room, etc. NOT specific square footage) * # of Returns * Associated Heating/Cooling Equipment Served by Duct System * Location of Duct Work (Attic (well vented), Attic (well vented, under insulation), Garage, etc.) * % Area of Each Location Type * Duct R-Values

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article