2024
Changes:
- SEER2 requirements of 15.2 for Tier 1 and 16+ for Tier 2.
- Lighting in elective requirements removed. Must meet 2 out of 4 elective requirements for Tier 1 and 3 out of 4 for Tier 2.
- Energy Star v3.1 Certification is added as an Innovation Option for Tier 1.
- Tier 2 Incentive Amount increased to $425.
Mandatory Program Requirements | ||
Tier 1 | Tier 2 | |
Minimum Cooling SEER2 Value | 15.2 | 16 |
Grade 1 Wall Insulation | Yes | Yes |
Grade 1 Ceiling Insulation | Yes | Yes |
5% Savings over TBRH | Yes | Yes |
Passes at least one: IECC 2015 Prescriptive, IECC 2015 Performance, Texas 2015 ERI, ENERGY STAR v3.1. | Yes | Yes |
Elective Requirements | Must Meet 2 out of 4 | Must Meet 3 out of 4 |
Duct Leakage CFM/100 sq. ft. | ≤ 4 | ≤ 4 |
Infiltration ACH50 | ≤ 4.5 | ≤ 4.5 |
Average Window SHGC | ≤ .24 | ≤ .24 |
Average Rated Wall + Sheathing R Value | ≥ 15 | ≥ 15 |
Innovation Options | Optional | Optional - Meet 1 out of 2 |
If you choose an innovation option, it will replace the Elective Requirements | Energy Star v3.1 Certification | Foam encapsulated envelope (R-13 walls and R-21 ceiling) or obtain ENERGY STAR v3.1 certification |
Incentive Amount | $225.00 | $425.00 |
Additional Bonus Incentives - Limit of one Bonus Incentive of each type per home. | ||
Right Sized HVAC (Submit Manual J) | $50.00 | |
ENERGY STAR Certified Smart Thermostat (Submit Model and Serial Number) | $50.00 |
2022 and 2023
For 2022 and 2023, TNMP has reduced the Tier 1 incentive to be $225. There are no changes to the requirements (see below).
2020
In addition to the requirements listed in the table below, the home also needs to exceed the baseline electricity performance by at least 5% and must pass one of the following energy codes: IECC 2015 Prescriptive, IECC 2015 Performance, Texas 2015 ERI, ENERGY STAR v3.1.
Mandatory Program Requirements | ||
Tier 1 | Tier 2 | |
Minimum Cooling SEER Value | 16 | 16 |
Grade 1 Wall Insulation | Yes | Yes |
Grade 1 Ceiling Insulation | Yes | Yes |
Elective Requirements | Must Meet 2 out of 5 | Must Meet 4 out of 5 |
Duct Leakage CFM/100 sq. ft. | ≤ 4 | ≤ 4 |
Infiltration ACH50 | ≤ 4.5 | ≤ 4.5 |
Average Window SHGC | ≤ .24 | ≤ .24 |
Average Rated Wall + Sheathing R Value | ≥ 15 | ≥ 15 |
High Efficiency Lighting % | ≥ 90% | ≥ 90% |
Innovation Options | Optional | Optional - Meet 1 out of 2 |
If you choose an innovation option, it will replace the Elective Requirements | Foam encapsulated envelope (R-13 walls and R-21 ceiling) or obtain ENERGY STAR v3.1 certification | |
Incentive Amount | $250.00 | $400.00 |
Additional Bonus Incentives - Builders can combine additional bonus incentives for a total of $75 for either tier | ||
Right Sized HVAC (Submit Manual J) | $25.00 | |
ENERGY STAR Certified Smart Thermostat (Submit Model and Serial Number) | $50.00 |