V8 Predrywall QA Q18: CoolingSys

Modified on Tue, 5 May at 4:18 PM

PHOTOS REQUIRED of Cooling System (Coil and Condenser) nameplate/model number per HERS® Standards Chapter 9. Raters/RFIs are responsible for documenting reasons for missing photos. If installed, Rater/RFI verifies and documents the correct space cooling system type(s), fuel type(s), location(s), and number of unit(s).

  • Photographs of installed air handlers, coils, ductless heads, non-split systems, and outside units will capture at a minimum: - Type(s) - Nameplate(s)/Model Number(s) and Control(s) - Location(s) (This should be a wider shot to be able to identify the location) - Fuel(s) used for each system (Photos of meters and tanks can capture fuels used in the home, but also need to identify per system if multiple fuels are used) *Photographs of installed Ground Source Heat Pumps (GSHP) will capture at a minimum: - Closed-Loop (brine) systems or Open-Loop (water source) systems - Pump nameplate to capture the pump energy - Wells: Rater/RFI verifies and documents the correct well type, number of wells, well depth, and loop flow.

SCORING: (These errors are assessed per Cooling System; the same error can occur multiple times if there are multiple Cooling Systems and should be added to the overall total) "Satisfactory": When all mandatory photos are provided, and no errors in verification "1": One error (listed below) "2": Two errors (listed below) "3": Three or more errors OR incorrectly identifying the number of units (listed below) "Missing Photo": One or more of the mandatory photos are missing, and no errors in verification "Missing Photo + "1": One or more of the mandatory photos are missing, plus "1" per scoring above "Missing Photo + "2": One or more of the mandatory photos are missing, plus "2" per scoring above "Missing Photo + "3": One or more of the mandatory photos are missing, plus "3" per scoring above "N/A": No Cooling System in home

GUIDANCE: Cooling System Verification Errors - The Rater/RFI can correctly identify or determine the following items: * Equipment Type(s) * Location for each System * Fuel Type(s) * GSHP - Open or Closed Loop * GSHP - Pump Energy * GSHP - Well Type, Number of Wells, Well Depth, and Loop Flow

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article