FF_Q32_VentilationSystemTesting Version 7.1.1

Modified on Wed, 29 Jan at 5:20 PM

PHOTO REQUIRED of Mechanical Ventilation Test Results, equipment nameplate/model number and controls per MINHERS Chapter 9. Raters/RFIs are responsible for documenting reasons for missing photos. Mechanical Ventilation is tested according to ANSI/RESNET/ICC 380. Rater/RFI verifies and documents the correct ventilation type, frequency, flow and wattage.

  • Ventilation wattage can be verified via published OEM data, third party database (i.e. HVI.org) or on-site measurement via Watt meter.
  • Air flow measurement methods are described in ANSI/RESNET/ICC 380. Rater/RFI correctly notes whether or not they perform the testing.
  • Usage of Operable Windows (Natural Ventilation): Confirm that the type of ventilation that occurs or is most likely to occur matches the Cooling Season Strategy: 'No Ventilation', 'Natural Ventilation', or 'Whole House Fan'.

SCORING:

Satisfactory: <10% variance between QAD result and Rater/RFI result

  1. 10% to <15% variance between QAD result and Rater/RFI result
  2. 15% to 25% variance between QAD result and Rater/RFI result
  3. 25% variance between QAD result and Rater/RFI result

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article