If applicable/visible, Rater/RFI verifies and documents the correct rim and band joist surface areas, joist spacings, locations and insulation R-values, thicknesses and grades. Where multiple rim/band joists types exist, they are handled separately, including where their “location” with respect to conditioned areas of the home may vary between rim and band types and within the same rim and band type. Photos of R-Value and Grading is recommended but not required.
SCORING:
"Satisfactory": When correct
"Unsatisfactory": When incorrect
"N/A": No Rim/Band Joists in the home
GUIDANCE: Rim/Band Joist Verification Errors - The Rater/RFI can correctly identify or determine the following items (if installed at the time of the pre-drywall inspection): * Surface Area is appropriately measured and documented * R-Value and Grading