V7.1.1 Field QA Q31: TestCorrectionFactorsApplied

Modified on Tue, 5 May at 4:18 PM

Rater/RFI verifies and documents the correct altitude, indoor temperature and outdoor temperature, and then adjusts the CFM50 results with these factors. If single point infiltration testing is used, Rater/RFI also applies the 1.1 single point correction factor to the test result after it is corrected for altitude and temperature.

  • Ensure that test results are correctly documented as single point or multi-point.

SCORING:

"Satisfactory" when correct or "Unsatisfactory" when incorrect.