Heat Pumps without AHRI HSPF Ratings

Modified on Sat, 26 Mar 2022 at 01:24 PM

In some cases, a system may be certified by the AHRI but may not have an HSPF rating listed on the AHRI Certificate.


In these cases, Ekotrope recommends using the following table to determine HSPF based on the COP at 47 degrees Fahrenheit. This table was developed based on a recreation of the AHRI HSPF calculation procedure for region IV (the standard HSPF region) and 17F and 35F COPs derived based on a standard heat pump performance curve from NREL published research (Cutler, et. al. 2013).


 

COP @ 47FHSPF
37.54
3.27.93
3.48.31
3.68.68
3.89.05
49.40
4.29.75
4.410.08
4.610.41

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select atleast one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article